Technical Data

Material Test Standards Documentation

Handy-Shield MAXX™, Trap Gear™, Soft PVC Insulation Material

Fire Safety

ASTM E84 Flame Smoke Test

Download PDF

ASTM C177 Test Results

Thermal Conductivity and Resistance Testing

Download PDF

ASTM C518 Test

Thermal Resistance and Density Testing

Download PDF

Long Term Degradation Testing

Durable PVC Material Testing

Download PDF

ASTM G-21 Test Results

Interior and Exterior surface tested with Result of -0- Fungal

Download PDF

ASTM E84-07: 25 Flame/450 Smoke Class A Material Tested

ASTM E84 is a Referenced & Adopted Standard of the International Building Code

ASTM C177: Thermal Conductivity 0.028 (K-Value) | Thermal Resistance 0.504 (R-Value)

ASTM C518: Thermal Conductivity 0.358 (avg.) | Thermal Resistance 0.346 (avg.) | Thermal Resistance 2.790 ("R" Per Inch) | Density 21.61 (PCF)

Material Durability Tests:

ASTM G153 - Weatherization & UV

ASTM D412 - Tensile Strength and Elongation

ASTM D570 - Water Absorption

Laws Codes & Standards Compliance

ADA 4.19.4, ICC/ANSI A117.1, ADAAG 606.5, ABA 606.5

International Building Code (IBC)

General Services Administration (GSA) P-100

2009 US Army Corps of Engineers/Military Facilities Specification (ASTM E84)

UPC/IAPMO Material & Property Standard PS94, 2008

ASTM E84-07. 25 Flame/450 Smoke Class A Material Tested

ASTM E84 Is a Referenced & Adopted Standard of the International Building Code

Fire Safety for ADA & Building Code Compliance

U.S. Fire Administration Research

School Fires Report (14,700 annually)

Download PDF from FEMA

Pipe Insulation and Fire Safety Report

By Marcelo Hirschler PhD

Download PDF Hirshler Report

Anatomy of ANSI A117 and ICC Codes

By Saum Nour PhD

Download PDF Nour Report

North American Coalition Fire & Life Safety

For "At Risk Groups"

Download PDF Beyond Solutions 2020

Department of Justice ADA Final Rule 2010

The Department, as a member of the Access Board, was an active participant in the lengthy process of developing the 2004 ADAAG, on which the 2010 Standards are based. As part of this update, the Board has made its guidelines more consistent with model building codes, such as the IBC, and industry standards.

Building Code (IBC) Chapter 11 Accessibility

1101.1 Scope: The provisions of this chapter shall control the design and construction of facilities for accessibility to physically disabled persons.

1101.2 Design: Buildings and facilities shall be designed and constructed to be accessible in accordance with this code and ICC A117.1.

International Building Code (IBC) 2006 Chapter 8 Interior Finishes

806.5 Material other than foam plastic used as interior trim shall have a minimum Class C flame spread and smoke-developed index when tested in accordance with ASTM E84.

TRIM: Picture molds, chair rails, baseboards, handrails, door and window frames and similar decorative or protective material used in fixed applications.

*All trim must be a minimum of Class C. Combustible trim may not exceed 10 percent of the area of the aggregate wall or ceiling area.

Design & Construction Responsibility

Compliance with the ADA is 'non-delegable' in that any parties in the design and construction of a building or facility cannot 'insulate himself from liability by relinquishing responsibility to another party. "Everyone who participates in the design and construction of a building shares responsibility to follow the law," added Bill Lann Lee, Assistant Attorney General, US v. Days Inn, Dept of Justice Agreement.

Whole Building Design Guide

National Institute of Building Sciences (NIBS)

Providing equal access means ensuring all individuals can make use of transportation, buildings and facilities, programs and services, employment opportunities, and technology. It also means offering all users the same provisions for privacy, security, and safety. Providing equal access is required, to varying degrees, in order to meet applicable building codes, accessibility standards, and accessibility guidelines.